Jump to content

Requests for technical support from the VASP team should be posted in the VASP Forum.

ENCUTGWSOFT

From VASP Wiki
Revision as of 12:26, 23 November 2021 by Kaltakm (talk | contribs)

ENCUTGWSOFT = [real] 

Default: ENCUTGWSOFT = ENCUTGW[math]\displaystyle{ \times 0.8 }[/math] for ALGO=ACFDT
= ENCUTGW[math]\displaystyle{ \times 0.8 }[/math] as of VASP.6.3
= ENCUTGW else

Descprition: The flag ENCUTGWSOFT sets the energy cutoff for response function, such that it allows to truncate the Coulomb kernel slowly between the energy specified by ENCUTGWSOFT and ENCUTGW.


This usually leads to much smoother energy-volume curves in ACFDT calculations and MP2 calculations. The modified Coulomb kernel is in this case: [math]\displaystyle{ v_{\bold{G}} = \frac{4 \pi e^2} {G^2} \frac{1}{2} \left( 1 + \cos \left( \pi \, \frac{ \frac{\hbar^{2} G^2 }{2 m_e} - \mathrm{ ENCUTGWSOFT} }{ \mathrm{ENCUTGW} - \mathrm{ENCUTGWSOFT}} \right) \right) \qquad \mbox{for} \quad \frac{\hbar^2 G^2 }{2 m_e} > \mathrm{ENCUTGWSOFT} }[/math]

If LSCK is set to .TRUE., the squeezed Coulomb kernel is used instead of the cosine window:[1]

[math]\displaystyle{ v_{\bold{G}} = \frac{4 \pi e^2} {| \bold{G}|^2} \frac{1}{2} \left( 1 + \cos \left( \pi \, \frac{ \frac{\hbar^{2} |\bold{G}|^2 }{2 m_e} - \mathrm{ ENCUTGWSOFT} }{ \mathrm{ENCUTGW} - \mathrm{ENCUTGWSOFT}} \right) \right) \qquad \mbox{for} \quad G_{min}<G<G_{max} }[/math]

where [math]\displaystyle{ \hbar^2 G_{max} = \mathrm{ENCUTGW} }[/math]

Related Tags and Sections

PRECFOCK, ENCUT, ENCUTGW, GW calculations, LSCK

Examples that use this tag


Contents